Download and install Huygens Professional from the SVI website: https://svi.nl/Download
If you can´t download the software yourself, please contact the Imaging Network to get the latest version.
To install the license, launch Huygens Professional version and go to 'License overview' at the pull-down of 'Help'. Click on the 'Add new license' button, paste the license in and press 'Add license'. Close the program and reopen it. Now the license is activated. If you are using a GPU, please check if the GPU option is running. Click on the 3rd Icon from the left and follow the instruction if necessary.
How to get the Network license?
Please contact the Imaging Network to get the actual license for Huygens Professional
You can find out the optimal sampling for deconvolution by using the Nyquist calculator:
https://svi.nl/NyquistCalculator (also available as app for smartphones). For a confocal with 1.4 NA lens and 488 excitation the optimal sampling is xy: 43nm, z: 130nm. This is about 2x the resolution which the software of the microscope indicates as optimal.
Use the Deconvolution Wizard by clicking the magic wand in the menu icon list or right-click on your image. Read the explanations and click next. The 'Auto' modes working fine for most images. At the 'Deconvolution Setup' window press 'Deconvolution preview' to check your current settings. If the result is to noisy, lower the signal to noise ratio value. Increase the value to get a higher resolution. As a very basic approach, the following values can be used as a first estimation of the SNR of different image types:
- Bad quality confocal image: SNR = 10
- Normal confocal image: SNR = 20
- Good quality confocal image: SNR = 30-60
- Good quality widefield image: SNR > 40
If the image noise is clearly amplified after the restoration then the SNR value provided to the deconvolution algorithm was too high. On the contrary, if the restored image looks too smooth then the SNR value was too low. In both cases, please proceed to restore the raw data again with an adapted SNR value.
How to deconvolve TIRF images?
TIRF (Total Internal Reflection Fluorescence) deals mostly with 2D images. Huygens can handle 2D images by internally treating them as part of a 3D stack from which most planes happen to be missing. Strictly speaking Huygens does not generate TIRF Theoretical PSFs, but customers report good results with high NA confocal PSFs. Proceed by setting the Microscope type of your image to confocal and NA ~ 1.4.
You can save your image in different formats. The ICS (2) format is an open source format from SVI and can be read by Fiji. If you want to save as 16bit Tiff, you may have to decide how to scale your image to the Dynamic Range.
Contrast stretch: positive data range for each channel is adapted to the Tiff range, the different per-channel factors are not reported
Linked scale: as stretch, but now the relation between channels is retained: the same factor is applied to all channels that stretches the one with maximum intensity to the Tiff range. The factor is reported by Huygens.
Clip: positive data outside the Tiff range is clipped to that range.